Troubleshooting Guide for Crophesy Equipment

Troubleshooting Guide for Crophesy Equipment

Troubleshooting the Equipment and FAQ's

​

1.      I can’t see my site on the dashboard

·       Click the “Filter” button and change the status from “Planted” to “All” or “Year Planted”

​

2.      My sites are gone and I can’t see them on the website. How do I get them back?

·       To see your sites again, click on the Filter Button and change the STATUS  to Year Planted and Select the Year. 

​

3.      How do I get my data from the past season?

·       To get data from the previous season, go to the site and in the FILTER, select STATUS Year Planted and the Year.

​

4.      How can I download my data via Excel or CSV?

·       You can go to the Water tab and click Export OR you can select the Orange Manage Sites and the Season Data Export Tab.

​

5.      I am still receiving emails even though my probed are extracted

·       There are two possibilities for this: 1. The physical extraction was completed but the digital extraction wasn’t. 2. The season length is automatically assigned by the system and even though your probe was extracted the season hasn’t ended.

​

6.      My probe isn’t working

·       First step to try, clean all connection points and inspect probe to ensure there is no animal/equipment damage.

·       LS-N Probe: Apply a small amount of rubbing alcohol to a lint‑free tissue and thoroughly clean the connectors on both the probe and the telemetry top.

·       Legacy Probe: Using a lint‑free tissue lightly moistened with rubbing alcohol, thoroughly clean the connectors on the probe, the CT, and both ends of the cord to ensure proper electrical contact.

​

7.      Is Nitrate-N data in ppm or lbs/acre per dry soil basis or per soil solution?

·       NO3-N ppm in soil solution

​

8.      My probe showed up as extracted but it wasn’t physically extracted

·       If your CT wasn’t connecting properly and remained inactive for 28 days it will automatically do a digital extraction in the system

​

9.      What’s good RSSI and bad RSSI signal strength

·       Between -50 and -85 is very good, between -85 and -100 the connection might begin to struggle, and anything over -100 is not a good signal strength

​

10. Why is my CT beeping?

·       The CT is likely low on battery. When the battery voltage drops too low, the CT will beep and enter sleep mode while it waits for the solar panel to recharge the battery in sunlight.

​

11. Why did my site stop reporting and suddenly show as "Out of Season"?

·       Crop season length is automatically determined by the system. If the site switches to "Out of Season" before harvest, the season length may need to be manually extended.

​

12. What is a good external voltage (ext. voltage) during full sun?

·       A healthy external voltage reading in full sunlight is typically 1.6-1.8 volts.

​

13. At what battery voltage does the probe stop reporting?

·       The probe will stop uploading data when the battery voltage drops to approximately 3.7 volts. The probe may continue collecting data internally, but it will not transmit data until the battery is recharged by the solar panel.

​

14. How can I find where my probe is located in the field?

·       Probe GPS coordinates can be viewed from the desktop version of the dashboard. Open the site and click Location on the main dashboard to view the probe's coordinates.

​

15. I created a new season, but when I try to complete the digital install, it says the equipment is already associated with another site.

·       The equipment is still associated with the previous season. To complete the install and associate the equipment with the new season, you must first complete the digital extraction from the previous season.